Lifeline VIEW AED The AED with a sight
Satisfy the AED that is taking user-friendly to an entire brand-new degree. Various other AEDs inform you what to perform in an emergency situation. The Lifeline VIEW is the initial and just one that programs you with a video clip in the full-motion shade. With acclaimed development, resilience, and simple upkeep - backed by the Defibtech dedication to development and quality - we could assurance you've never ever seen an AED such as this previously.

Defibtech Lifeline View AED
Defibtech Lifeline View AED

Full-Color Interactive Show
They state a photo deserves a thousand words; currently, increase that with the power of video clips. The Lifeline VIEW has a big, full-color interactive show that provides you detailed directions for carrying out CPR, save taking a breath, and outside defibrillation.

Real-time Procedure Choice
Not all rescuers coincide. Some individuals do compression-only CPR. Others might learn to do both compressions and save taking a breath. Real-time Procedure Choice enables you to switch over from one to both without avoiding a defeat, providing you the convenience and self-confidence to provide emergency situation treatment your method.

Easy to Utilize
Among the significant issues with many AEDS is upkeep. Not with the Lifeline VIEW. The condition display provides you as much as the min info on upkeep if it is needed. Additionally, integrated video clip assistance provides you simple, detailed assistance on upkeep that supplements the individual hands-on. Positive coverage screens the condition of the gadget and its elements.

As procedures alter in time, your system could be quickly updated in the area with an information card. Information from the system could be tape-taped or recovered from the gadget utilizing an information card.

Risk-free and Efficient
The Lifeline VIEW utilizes biphasic innovation, a scientifically shown waveform and formula to provide shocks and conserve lives. This is among one of the most commonly utilized resistance compensated waveforms that has comprehensive medical experience-and success-in countless defibrillators worldwide. Assessment in numerous magazines has shown this innovation to be the best and more efficient when it concerns conserving lives.

An Individual Trainer at Your Side
While you're in the center of the save, you might not keep in mind the number of compressions to offer and the timing in between everyone. The Lifeline VIEW has an integrated metronome that matters out the defeat so you understand what to do when to do it.

Award-Winning Ergonomic Develop
Small, mobile, and lightweight-under 3 pounds-the Lifeline VIEW stands for the most recent generation in a household of defibrillators that have won a variety of market honors for development.

Resilient
The VIEW's ruggedness is determined by a particular established of requirements. It's one difficult bit system, triumphing in a few of one of the most requiring ecological examinations.

Ways to find and locate the pads
The initial action in effectively utilizing an AED is to location the pads in the appropriate setting for the client. The video clips will reveal detailed ways to prepare the client, discover the pads, link them, and precisely where to locate them.

Ways to do save taking a breath
The Defibtech VIEW AED enables the individual to select compression-only CPR or compressions with saving taking a breath. If save taking a breath is selected, the video clip will reveal to you exactly just how when to offer to save breaths.

Where to location hands for CPR
Appropriate positioning of the hands is crucial for carrying out CPR properly. A glimpse at the video clip will reveal precisely where you have to place your hands and ways to carry out compressions properly.

Defibtech Lifeline VIEW AED Semi-Automatic Defibrillator


Technological specs
Defibrillator
Kind
Semi-automatic outside defibrillator
Design
DDU-2300
Waveform
Biphasic Truncated Rapid (Resistance compensated)
Power
Grown-up: 150 Joules, Kid / Baby: 50 Joules (Small right into 50 Ohm load)
Manages
Lighted On / Off switch Lighted Stun switch
Bill Time*
Much less compared to 4 secs (from stun advised)
Show
High-resolution shade LCD
Video clip Triggers
Complete movement video clip On-screen message triggers
CPR Training
Video clip and articulate training On-demand video clip assistance
Articulate Triggers
Comprehensive articulate triggers direct individual with the procedure of the system
Save Procedure
AHA/ERC (default); sustains procedure updates by the individual (password protected)
*Typical, with a brand-new battery at 25C
Client Evaluation System
Client Evaluation
Immediately assesses client resistance for appropriate pad get in touch with Screens indicate high top quality and evaluates client ECG for shockable / non‐shockable rhythms
Level of sensitivity / Specificity
Satisfies or surpasses IEC-60601-2-4 requirements; satisfies AAMI DF80 demands and AHA suggestions
Battery Load
Design
DBP-2003 (standard), DBP-2013 (aviation; TSO C-142a)
Power
12V, 2800 mAh
Kind
Lithium/Manganese Dioxide Nonreusable, recyclable, non‐rechargeable
Capacity*
125 shocks or 8 hrs constant procedure
Standy Life*
4 years
Reduced Battery Signs
Noticeable Distinct
Self Examinations
Automated
Automated everyday, regular, regular month-to-month, and quarterly wiring examinations
Battery Insertion
System stability examination on battery insertion
Pad Existence
Pads preconnected evaluated every day
User-Initiated
System and battery load system examination started by the individual
Condition Display
Aesthetic and distinct indicator of system condition
Articulate Triggers
System self-test outcomes in Pads and battery info (condition and expiration)
Defibrillation / Tracking Pads
Design
Grown-up: DDP-2001
Kid / Baby: DDP-2002
Surface area Area**
Grown-up: 12 inches2 (77 cm2) Kid / Baby: 7.75 inches2 (50 cm2)
Kind
Pre-connected, single-use, non-polarized, nonreusable, self-adhesive electrodes with cable television and port
Occasion Paperwork
Interior Occasion Document
Crucial ECG sections and save occasion specifications are tape-taped (higher than 60 mins) and could be downloaded and install on a detachable information card
PC-Based Occasion Evaluate
ECG with occasion label show, and sound playback when offered
Detachable Storage space
(optional) As much as 30 hrs of ECG and occasion information storage space (no sound choice) or as much as 3 hrs of sound (sound option)
ECG and occasion storage space on a detachable information card. The real size of storage space depends on card capability
USB Port
Occasion download and install and upkeep procedures
Ecological
Temperature level
Running: 0 to 50C (32 to 122F)
One Hr Running Temperature level
Restrict (severe cold): -20C (-4F)***
Standby: 0 to 50C (32 to 122F)
Family member Moisture
Running / Standby: 5%-95% (non-condensing)
Elevation
-500 to 15,000 feet (-150 to 4500 m) each MIL-STD-810F 500.4 Treatment ll
Resonance
Ground (MIL-STD-810F 514.5 Classification 20) Helicopter (RTCA/DO-160D, Area 8.8.2, Feline R. Area 2, Contour G) Jet Airplane (RTCA/DO-160D Area 8, Feline H, Area 2, Contours B & R)
Stun / Go down Misuse Resistance
MIL-STD-810F 516.5 Treatment IV 48 inches (1.2 meters), any type of side, edge, or surface area, in standby setting
Securing / Sprinkle Resistance
IEC 60529 course IP55; Dirt Safeguarded, Safeguarded versus sprinkle jets (Battery load installed)
ESD
(EC 61000-4-2: (Open-air as much as 15kV or straight get in touch with as much as 8kV)
EMC (Emission)
CISPR 11 Team 1 Degree B and FCC Component 15
EMC (Immunity)
IEC 61000-4-3 and IEC 61000-4-8
Physical
Dimension
7.3 x 9.5 x 2.3 Inches (18.5 x 24 x 5.8 cm)
Weight (with battery)
Much less compared to 3 pounds (1.4 kg)
Short Recap of Indicators, Contraindications and Various other Essential Security Info
When ought the Defibtech Automated Outside Defibrillator (AED) be utilized - what are its indicators?
Lifeline/ReviveR VIEW DDU-2300 and Lifeline/ReviveR ECG DDU-2450 Automated Outside Defibrillators (AEDs) are suggested for utilizing on sufferers of unexpected heart arrest (SCA) that are:
Subconscious and less competent
Not taking a breath or otherwise taking a breath typically
Lifeline/ReviveR VIEW DDU-2300 and Lifeline/ReviveR ECG DDU-2450 AEDs might be utilized with Defibtech grown-up defibrillation pads (design number DDP-2001). For clients under 8 years of age, or evaluating much less compared to 55 pounds (25 kg), utilize Defibtech kid/baby defibrillation pads (design number DDP-2002) if offered.
When ought the Defibtech AED not be utilized - what are its contraindications?
Lifeline/ReviveR VIEW DDU-2300 and Lifeline/ReviveR ECG DDU-2450 Automated Outside Defibrillators (AEDs) ought to not be utilized if the sufferer is receptive or mindful.
What various other info is essential regarding utilizing the AED?
Don't hold-up treatment to identify the precise age or weight. If pediatric pads are not offered, use grown-up pads in the setting as revealed for a kid/ baby and utilize the AED.
What are the prospective unfavorable health and wellness impacts of utilizing an AED?
The prospective unfavorable impacts (e.g., problems) connected with the use of an automatic outside defibrillator consists of, however, are not restricted to, complying with:
Failing to determine shockable arrhythmia.
Failing to provide a defibrillation stun in the existence of VF or pulseless VT, which might outcome in a fatality or long-term injury.
Unsuitable power, which might trigger stopped working defibrillation or post-shock disorder.
Myocardial damages.
Terminate risk in the existence of high oxygen focus or flammable anesthetic representatives.
Improperly stunning a pulse maintaining rhythm and inducing VF or heart arrest.
Bystander stun from the client gets in touch with throughout defibrillation stun.
Communication with pacemakers.
Skin sheds about the defibrillation pads positioning location.
Sensitive dermatitis because of the level of sensitivity to the products utilized in the defibrillation pad building.
Small skin breakout.
What are a few of the appropriate cautions relates to the AED?
Comply with all battery load identifying directions. Don't set up battery packs after the expiry day.
Comply with all defibrillation pad tag directions. Utilize defibrillation pads before their expiry day.
Utilize and keep the DDU-2000 Collection AED just within the variety of ecological problems defined in the technological specs.
What are a few of the appropriate cautions relates to the AED?
Dangerous electric outcome. This device is for utilizing just by certified workers.
Feasible terminate or surge. Don't utilize in the existence of flammable gases or anesthetics. Utilize treatment when running this gadget shut to oxygen resources (such as bag-valve-mask gadgets or ventilator tubes). Shut off the gas resource or remove the resource far from the client throughout defibrillation, if required.
The DDU-2000 Collection AED has not been assessed or authorized for utilizing in dangerous places as specified in the Nationwide Electrical Code basic. In conformity with the IEC category, the DDU-2000 Collection AED isn't to be utilized in the existence of flammable compound/air mixtures.
Incorrect upkeep could trigger the DDU-2000 Collection AED not to work. Preserve the DDU-2000 Collection AED just as explained in the Individual Hands-on and Running Direct. The AED includes no user-serviceable components — don't take the system apart.
Don't open up closed pads bundle up till pads are to be utilized. The product packaging ought to be opened up just instantly before utilization, or else, the pads might dry and ended up being non-functional.
Don't touch the client throughout defibrillation. Defibrillation present could trigger driver or bystander injury.
The defibrillation pads are meant for single utilize just and should be disposed of after utilization. Recycle could result in prospective cross-infection, incorrect efficiency of the gadget, insufficient shipment of treatment, and/or injury to the client or driver.
CPR throughout evaluation could trigger inaccurate or postponed medical diagnosis by the client evaluation system.
User-initiated and automated self-tests are developed to evaluate the DDU-2000 Collection AED's preparedness for utilize. Nevertheless, no level of screening could guarantee efficiency or spot misuse, damages, or a problem that happened after one of the most current examinations is finished.
Also if defibrillation happens, the unexpected heart arrest occasion might not outcome in survival.
Care: Government (U.S.A.) legislation limits this gadget to sale by or like a doctor.
Please describe the Running Direct offered with your AED for individual directions, a total listing of cautions and cautions, driver educating demands, a recap of main medical research researches, technological specs, and various other essential info.